Case Study No. 405-1

Application:   Mining Equipment
Industry: Quarry
Problem: - Initially, manual lubrication twice a day
- Very difficult access.
- Irregular lubrication leading to components failures
- Machine stoppage and production losses
- No control of lubrication
Solution: Installation of 10 MEMOLUB® MEGA HPS with in
between 16 and 26 feet of piping, setting 15 days.